External validation of the 0/1h-algorithm and derivation of a 0/2h-algorithm using a new point-of-care Hs-cTnI assay
Koechlin, L., Boeddinghaus, J., Lopez-Ayala, P., Wildi, K., Nestelberger, T., Wussler, D., Guzman Tacla, C.A., Holder, T., Muench-Gerber, T., Glaeser, J., Yufera Sanchez, A., Miró, Ò., Martin-Sanchez, F.J., Kawecki, D., Buergler, F., Buser, A., Huré, G., Rubini Giménez, M., Keller, D.I., Christ, M., Mueller, C. American Heart Journal DOI: 10.1016/j.ahj.2023.11.014
Abstract:
Background: The high-sensitivity cardiac troponin (hs-cTn) I point-of-care (POC) hs-cTnI-PATHFAST assay has recently become clinically available. Methods: We aimed to externally validate the hs-cTnI-PATHFAST 0/1h-algorithm recently developed for the early diagnosis of non-ST-segment-elevation myocardial infarction (NSTEMI) and derive and validate a 0/2-algorithm in patients presenting to the emergency department with acute chest discomfort included in a multicenter diagnostic study. Two independent cardiologists centrally adjudicated the final diagnoses using all the clinical and study-specific information available including serial measurements of hs-cTnI-Architect. Results: Among 1,532 patients (median age 60 years, 33% [n = 501] women), NSTEMI was the final diagnosis in 13%. External validation of the hs-cTnI-PATHFAST 0/1h-algorithm showed very high negative predictive value (NPV; 100% [95%CI, 99.5%-100%]) and sensitivity 100% (95%CI, 98.2%-100%) for rule-out of NSTEMI. Positive predictive value (PPV) and specificity for rule-in of NSTEMI were high (74.9% [95%CI, 68.3%-80.5%] and 96.4% [95%CI, 95.2%-97.3%], respectively). Among 1,207 patients (median age 61 years, 32% [n = 391] women) available for the derivation (n = 848) and validation (n = 359) of the hs-cTnI-PATHFAST 0/2h-algorithm, a 0h-concentration <3 ng/L or a 0h-concentration <4 ng/L with a 2h-delta <4ng/L ruled-out NSTEMI in 52% of patients with a NPV of 100% (95%CI, 98-100) and sensitivity of 100% (95%CI, 92.9%-100%) in the validation cohort. A 0h-concentration ≥90ng/L or a 2h-delta ≥ 55ng/L ruled-in 38 patients (11%): PPV 81.6% (95%CI, 66.6-90.8), specificity 97.7% (95%CI, 95.4-98.9%). Conclusions: The POC hs-cTnI-PATHFAST assay allows rapid and effective rule-out and rule-in of NSTEMI using both a 0/1h- and a 0/2h-algorithm with high NPV/sensitivity for rule-out and high PPV/specificity for rule-in.